Safety and reliability in your processes have been our premise for the development of the samValve BF series 1. It is suitable for liquids and viscous media in tanks, containers and tubes. The high quality of sampling is achieved by a construction with very little dead storage. It can be mounted on tubes as well as on tanks. Furthermore, the samValve BF series 1 can be used under pressure up to 15bar and vacuum conditions and is absolutely leak free. By using different sealing materials the valve can be operated at temperatures up to 350°C. Due to the blind hole bowl it is without doubt the most secure sampling valve at all.
![]() | ![]() | ||
The samValve BF series 1 has two handles:
Position 1
Valve in normal rest position as shown in Fig. B with full pressure on the seals allowing ball cup and outlet to drain or to be cleaned.
Position 2
Seal pressure handle lifted to reduce pressure on seals and upper handle rotated through 180° to sampling position as shown in Fig. A. In this position air rises from the cup, which then fills with a clean sample. This can be done with the vessel under full vacuum or pressure.
Position 3
Valve rotated through 180° to empty sample via the nozzle into a suitable sample collection container (Fig. B). Each cycle from Position 2 to Position 1 takes from 40ml to 60ml of sample depending on viscosity. The cycle can be repeated any number of times to take the required total sample volume. Upon completion of sampling the lower handle is moved to re-apply full pressure onto the seals which then returns the valve to Position 1 above.