SamControl-L with adapter and bottle |
Temperatures: -20°C to +150°C
Pressure range: 1mbar to + 25bar
Leakage safe thanks to pressure barriere construction.
3-part housing, ball with dead end drilling, standard ball for granule material. Blowout safe spindle, self adjusting spindle sealing, dead-space filling ball seats, piggable, dead-space free and as a result representative fresh sample, easy cleaning, easy dismounting, with blocking also in the pipeline, screw-in adapter with deaeration 1/4" for glass thread GL45 or GL32 or after sample.
| DED-SACOL-09802.pdf | |||
| DEA-SLPFA-09809.pdf |