The manual coulombmeter, type CM 200, is suitable for determining the igneiteability of electrical discharges such as brush discharges or sparks up to 200nC, for instance on plastics surfaces, RIBC´s, FIBC´s and electrostatic spray systems.
Technical Date:
test range: +/-5 to +/-200nC, high definition automatic recognition of a discharge from 5nC on
protection class: IP 40
accuracy: 1nC at 100nC (calibrated)
indication: multifunctional graphic display. Storing up to 450 measuring values. Indicating the max. measuring value. Time stop function.
power supply: 2*AA batteries or accu
length: 330mm
diameter: 120mm
weight: 900g
operating temperature: + 5°C to + 45°C max, 65% r.F.
delivery scope: calibrated Coulombmeter, operating manual, cable for earth connection, carrying case, 2 pcs. AA batteries
Charge tests according to DIN EN 13463-1:2009-07 Annex D of non-conductive Materials can be performed with the CM 200.
We will be pleased to convey the skills.
© 2009 KERSTING GMBH SAMPLING + GROUNDING